You have assembled and wired the unit. Now, let’s power it on.

Calibration Tip: If the timer runs too fast or too slow, the mechanical timer may need replacing. There is no user calibration for the timer—replace it if inaccurate.


Elena grabbed a rolling stool and sat in front of the machine. She reached out and swung the hood over her head. The ergonomic handgrip was cool to the touch. She tilted the visor;

Your Wella Climazon Millennium box (or used unit) should contain:

Identify the connection type:

Manually installing a Wella Climazon Millennium is not a 5-minute job. However, following this guide ensures your dryer delivers consistent, salon-quality results for a decade or more. The key takeaways:

If you encounter a variation not covered here (e.g., the "Climazon Millennium II" or "Digital" variants), the manual install principles remain identical – only the control panel layout changes.

Still stuck? Contact Wella Service Support with your serial number. Do not force the arm or modify the internal wiring.


Article last updated: [Insert current date]. Specifications based on Wella Climazon Millennium Service Manual v3.2.

The Wella Climazon Millennium is a professional infrared heat processor used for hair colouring, bleaching, and treatments. For a safe and stable installation, you must follow specific requirements based on whether you are using the Pedestal (Stand) or Wall-Mounted version. Pre-Installation Requirements

Voltage: Ensure your outlet matches the unit's rating (typically 220–240V or 110–120V depending on your region).

Safety Clearance: Maintain at least 20 cm of free space around the heating elements for proper ventilation.

Wall Integrity: For wall-mounted versions, the wall must be solid (concrete or reinforced studs) to support the weight and movement of the Acrobat 2004 Wall Arm. Installation Steps 1. Pedestal (Stand) Version

Base Assembly: Insert the casters into the base (ST5 type) and secure them.

Column Attachment: Slide the main stand pipe into the base and tighten the locking screw firmly.

Mounting the Unit: Carefully place the Climazon head onto the stand tube. Ensure the cable holder is utilized to prevent the power cord from getting caught in the wheels. 2. Wall-Mounted Version

Mounting Plate: Secure the wall bracket (WA04/75 or WA04/95) at a height that allows for full articulation. Arm Attachment: Attach the Acrobat 2004 support arm

Wiring: Connect the internal power cable through the arm. It is highly recommended that a certified electrician performs the final wiring to comply with local safety standards. Key Controls & Components

Heating Elements: Features five infrared heaters. The side arms are foldable and adjustable into three different positions.

Customer Button: Allows the client to manually lower the treatment temperature for comfort. Blue Light: Lowered temperature. Red Light: Standard operating temperature.

Main Switch: Located at the base of the control panel for powering the unit on/off.

For detailed technical diagrams and maintenance instructions, you can refer to the official Climazon Operational Guide provided by Wella Professionals.

You're looking for a manual installation guide for the Wella Climazon Millenium!

The Wella Climazon Millenium is a popular hair straightening and styling tool. Here's a step-by-step manual installation guide to help you get started:

Before You Begin:

Installation Steps:

Using the Wella Climazon Millenium:

Safety Precautions:

The Wella Climazon Millennium (and its successor, the Climazon 2) is a professional hair-drying and heat-treatment device that can be installed in two primary configurations: as a pedestal/stand version or a wall-mounted version. Installation Configurations

Pedestal (Stand) Version: Uses the ST5 tripod base. This setup includes a mobile base with three rollers and a tripod tube for portability within the salon.

Wall-Mounted Version: Typically utilizes the Acrobat 2004 wall arm (models WA04/75 or WA04/95). This arm consists of a boom and a spring arm for flexible positioning. Key Installation Components

Based on official Wella Professionals documentation, the following mounting variants are supported: Wall Bearing (WL04): The base mount for wall installations.

Ceiling Mounting (DB04/2): For salons requiring overhead heat sources.

Floor Mounting: Options include one-piece (BB04/1) or two-piece (BB04/2) floor mounts.

Furniture Flange (FM04): For mounting directly onto salon furniture structures. Standard Specifications for Install Power Supply: Requires a standard 220V–240V outlet.

Dimensions: Approximately 1350mm high, 850mm deep, and 600mm wide (mobile version).

Safety Features: Includes a main ON/OFF switch and a cable holder specifically for the pedestal version to secure the power line. Installation Resources

For detailed step-by-step visual guides and specific technical load-bearing requirements, you can download official manuals directly from the Wella Professionals Appliance Page. Commonly used manuals include: Climazon S4 Appliance Head Manual Acrobat 2004 Wall Arm Manual.

Installing a Wella Climazon Millenium is a critical task for any modern salon seeking to provide high-end color, permanent wave, or care treatments. Proper installation ensures the safety of your staff and clients while maximizing the longevity of this sophisticated infrared hair processor.

This guide provides a comprehensive overview of the manual installation process for both the pedestal and wall-mounted versions of the Climazon. 1. Pre-Installation: Choosing Your Configuration

The Wella Climazon Millenium typically comes in two primary configurations:

Pedestal (Mobile) Version: Ideal for salons that need to move the device between different styling stations.

Wall-Mounted Version: Best for saving floor space, using the Acrobat 2004 wall arm (Type WA04/75 or WA04/95). 2. Pedestal Version Installation Steps

The mobile unit is mounted on a height-adjustable stand with rollers (typically the ST5 tripod).

Assemble the Base: Secure the tripod feet (Type ST5) with the rollers provided.

Insert the Tripod Tube: Fit the tripod tube (Type ST5) into the base and ensure it is tightened according to the manual.

Attach the Appliance Head: Carefully place the Climazon head onto the tube. Secure it using the cable holder, which doubles as a safety lock to prevent the head from detaching.

Connect Power: Route the power cable through the designated cable holder and plug it into a standard grounded outlet. 3. Wall-Mounted Version Installation Steps

Installing the wall-mounted version requires structural verification of your salon wall to ensure it can support the weight and movement of the Acrobat wall arm.

Mount the Wall Bearing: Fix the wall bearing (Type WL04) to the wall at the recommended height.

Attach the Extension Arm: Slot the boom (extension arm) into the wall bearing. Ensure the brake screws are adjusted to allow smooth but controlled movement.

Install the Spring Arm: Attach the spring arm (Type WA04) to the boom. This component allows for vertical height adjustment.

Calibrate Load Capacity: Use the adjustment opening on the spring arm to set the load capacity. This ensures the device stays at the desired height without drifting up or down. wella climazon millenium manual install

Final Security: Attach the protective caps to the arm joints to protect against electrical shock and mechanical pinching. 4. Technical and Electrical Setup

Power Supply: Ensure your salon’s electrical system matches the device's requirements. Both versions include a country-specific mains plug.

Temperature Sensor: Before first use, verify the temperature sensor (located in the center of the head) is fitted with its protective filter to prevent contamination.

Language Settings: Upon first powering on, use the SETTING button to navigate the menu and select your preferred language (the device supports up to 18 languages). 5. Post-Installation Safety Check Before treating your first client, perform a test run:

Ensure all five heating elements move freely and lock into their three standard positions.

Test the "Customer Button," which allows the client to manually lower the temperature for comfort.

Check that the air vents for the heating elements are unobstructed.

For detailed technical diagrams and specific torque settings, you should download the official Climazon Manual from the Wella Professionals Website.

Installing a Wella Climazon Millennium (or the updated Climazon 2) requires precise mounting to ensure the heavy articulating arm is secure and the electrical components are safe. Quick Setup Guide & Resources

For the Wall-Mounted Version, the system typically uses the Acrobat 2004 arm (Types WA04/75 or WA04/95).

Official Installation PDF: You can find the comprehensive manual for the appliance head and wall arm on the Wella Professionals Climazon Page.

Alternative Manual Access: Technical details for mounting and maintenance are also hosted on ManualsLib. Key Installation Steps Component Installation Detail Wall Mount

Must be fixed to a load-bearing wall using the specific Wandlager Typ WL04. Height Adjust

The Spring Arm (Federarm) has a specific opening (b) for setting the height stop and another (c) for adjusting load capacity. Electrical

Ensure the main ON/OFF switch (8) is accessible and the plug (b) is correctly seated in the wall outlet. Arm Tension

Use the two brake screws (8) on the boom to adjust how easily the arm swings. Safety & Maintenance Tips

Cool Down: Before any maintenance or cleaning, let the device cool for at least 10 minutes.

Cleaning: Use a soft, damp cloth with mild detergent; never use flammable substances like gasoline or lacquer thinner.

Sensors: The Millennium/Climazon 2 features infrared sensors that protect the client's ears and face; ensure these filters are kept clean for accurate temperature control.

The Wella Climazon Millenium (and its successor, the Climazon²) is a professional salon infrared processor known for its precision and durability. While the installation process is straightforward, it requires specific technical considerations for safety and stability. Installation Options & Reviews

The Climazon Millenium is primarily available in two configurations, each with unique installation pros and cons: Wall-Mounted (Acrobat 2004 Arm)

Review: This is the preferred choice for space-saving in busy salons.

Installation Note: Requires a heavy-duty wall bracket (Type WL04). It is critical to mount this to a structural stud or reinforced wall, as the "Acrobat" arm exerts significant leverage when fully extended. Pedestal (ST5 Stand)

Review: Offers the most flexibility, allowing you to move the unit between stations.

Installation Note: Setup is simpler than the wall mount; the head units typically lock into the ST5 stand with a secure cable holder to prevent tipping. Technical Setup Requirements

Electrical: Ensure your salon’s power supply matches the unit's voltage requirements (usually 220-240V for EU/UK models). You have assembled and wired the unit

Adjustments: Both the wall arm and pedestal versions allow for tension adjustments. The wall arm has a specific screw to set the "load-bearing capacity" so the head doesn't drift downward during use.

Safety Clearance: Professional reviews emphasize leaving enough clearance for the side arms to swing open fully, as these are adjustable for customized heat distribution. User Experience Tips

Low Noise: Users highly praise the unit's quiet operation compared to traditional hood dryers, making it easier for clients to talk during treatments.

Heat Protection: The "Skin Heat Protection" feature directs heat away from the client’s face and ears, which is a major comfort upgrade highlighted in salon reviews.

Are you looking to install a new unit yourself, or are you trying to troubleshoot an existing one?

A useful feature of the Wella Climazon² (often referred to as the Millenium in some markets) is its adaptable heating architecture, which utilizes five adjustable infrared heating elements that allow for targeted treatment delivery. Key Features for Installation & Setup

When installing or configuring the unit, these manual features provide significant versatility:

Moveable Side Arms: The side arms are foldable and the side heaters are adjustable into three different positions, allowing you to tailor the hood-like drying effect to the specific head shape or hair length of a client.

Mounting Flexibility: The device can be installed in several configurations depending on your salon space, including a pedestal version (ST5 tripod base) or various wall and ceiling mounts using the Acrobat 2004 wall arm system.

Adjustable Height & Tension: For wall-mounted installations, the Acrobat 2004 wall arm includes openings to manually set the height stop and the load capacity (tension), ensuring the arm stays exactly where you position it.

Customer Temperature Control: The unit includes a "Customer Button" that allows the client to manually lower the treatment temperature themselves for personalized comfort.

Specialized Program Modes: The software includes dedicated settings for different chemical processes (Color, Perm, Care, or Drying) that can reduce treatment time by up to 33% compared to standard drying.

For detailed installation steps and safety specifications, you can refer to the official Climazon² User Manual. Climazon | Hood Hair Dryer - Wella Professionals

Installing a Wella Climazon Millenium requires different setups depending on whether you are using a mobile floor stand wall-mounted arm . For safety, wall-mounted installations

be performed by a technical specialist or qualified electrician to ensure secure fixing and proper electrical connection. Wella Professionals Installation Configurations

The Wella Climazon is compatible with several mounting systems, most commonly the Acrobat 2004 arm or the ST5 pedestal Wella Professionals Wall Version

: Typically uses the Acrobat 2004 Wandarm (Type WA04/75 or WA04/95). Floor Version

: Utilizes the ST5 tripod foot with three rollers and an ST5 tripod tube. Other Options

: Approved variants include ceiling mounts (DB04/2), floor-fixed mounts (BB04/1 or BB04/2), and furniture flanges (FM04). Wella Professionals Critical Installation & Safety Steps Specialist Assembly (Wall-Mount)

: The wall version requires precise electrical work and high-strength wall fixing. Professional installation is mandatory to prevent the unit from falling. Spring Arm Caution

: The wall-mounted arm contains a high-tension spring. Never dismantle the arm without following the specific safety release protocols in the Wella Climazon Manual to avoid sudden recoil and injury. Pedestal Compatibility

use the appliance with the older Wella ST3 pedestal. The unit may become unstable and fall, causing injury. Device Setup Ensure the main ON/OFF switch (8) is accessible.

For tripod versions, use the cable holder (9) to secure the power lead to the ST5 stand.

Check that the five heating elements—including the foldable side arms—can move freely into their three adjustable positions. Wella Professionals Technical Specifications Mains Voltage : AC 220–240 V. Mains Frequency : 50/60 Hz. Rated Power : 1,350 W. Components

: Features a digital control panel, integrated temperature sensors with protective filters, and adjustable side arms for uniform heat distribution. Wella Professionals

For detailed wiring diagrams or specific mounting plate dimensions, consult the official Wella Acrobat 2004 Installation Guide programming steps Calibration Tip: If the timer runs too fast

for setting up specific color or drying treatments once the installation is complete?