V2000-c Rfid Access Control User Manual

Incorrect wiring is the #1 cause of V2000-c failure. Always disconnect power before wiring. Refer to the pinout diagram (usually on the rear of the device).

The V2000-c supports three operational modes. Switch using [Master Code] + # + 19 [Mode] #.

| Mode | Code | Behavior | Best Use | | :--- | :--- | :--- | :--- | | Card Only | 19 0 # | Swipe or PIN keypad. Relay activates. | Standard office, no high security. | | Card + PIN | 19 1 # | User must swipe AND enter PIN. | High-security server rooms, labs. | | Card or PIN | 19 2 # | Either a valid card OR a valid PIN works. | Convenience stores, gyms. |


The V2000-c provides a practical, cost-effective entry solution for many installations. With correct installation, strict admin practices, and routine maintenance, it will deliver reliable daily operation and straightforward auditing. Balance convenience and security by using encrypted channels and two-factor methods where possible, and always comply with local egress and fire safety regulations.

If you’d like, I can:

V2000-C RFID Access Control is a standalone single-door security system designed for offices, residential buildings, and secure facilities. It supports up to 1000 users

and multiple entry modes including RFID cards (125KHz), PIN codes, or a combination of both. Sesame Access Co., Ltd. Technical Specifications Specification Power Supply 12VDC ± 10% User Capacity 1000 users Reading Distance 3 – 8 cm (1.18~2.36in) 125KHz EM Standard Unlock Relay Door Open Time Adjustable from 0 to 99 seconds Dimensions 119 x 76 x 21 mm (some models 118 x 118 x 20 mm) Installation and Wiring The unit should be mounted approximately 1.2 meters above the ground and roughly 0.5 meters from the door for optimal accessibility. +12V DC power. Black Wire: GND (Ground). Purple Wires: Doorbell button output. Wiegand Interface:

Supports WG26 for connecting external readers or controllers. www.goldbridgesz.com Programming Guide V2000-c Access Control Manual - Facebook V2000-c Rfid Access Control User Manual

The V2000-C RFID Access Control system is a standalone device supporting up to 2,000 users with card-only, PIN-only, or combined verification modes for single-door security. It features a stainless steel design, 12V DC power requirements, and supports Wiegand 26-bit interfacing for integration. Detailed instructions for installation and user enrollment can be found in the savebase.com manual www.goldbridgesz.com

V2000-C RFID Access Control User Manual: Installation and Programming Guide

The V2000-C RFID Access Control system is a versatile, standalone security solution designed for small to medium-sized businesses, residential complexes, and secure storage areas. This manual provides a step-by-step guide on how to install, wire, and program your device to ensure maximum security. 1. Technical Specifications

Before installation, ensure your environment meets the following requirements: Operating Voltage: DC 12V ±10% User Capacity: 1,000 to 2,500 users (model dependent) Card Reading Distance: 3–6 cm Card Type: ID (EM) card or IC (Mifare) card Output Interface: Wiegand 26 (for external readers) Lock Output Load: Max 3A 2. Installation and Wiring

Mount the unit on a flat surface away from extreme heat or moisture. Follow the wiring diagram below to connect the unit to your power supply and electronic lock. Wiring Terminal Definitions: Red: +12V DC (Power) Black: GND (Ground) White: OPEN (Exit Button) Blue: COM (Relay Common) Yellow: NO (Normally Open – for Fail-Secure locks)

Green: NC (Normally Closed – for Fail-Safe/Magnetic locks) Grey: BELL (Doorbell connection) 3. Programming Guide

To enter programming mode, you must use the Master Code. The default master code is usually 990101 or 123456. Enter/Exit Programming Mode Press * + [Master Code] + #. (The LED will turn red/flash). Press * to exit programming mode at any time. Change the Master Code Incorrect wiring is the #1 cause of V2000-c failure

It is highly recommended to change the default code immediately.

Enter Programming Mode -> Press 0 + [New 6-digit Code] + # + [Repeat New Code] + #. Adding Users (Card or Keyfob) Enter Programming Mode. Press 1 + [Read Card] + #.

To add multiple cards, read them one after another, then press # to finish. Adding Users (Personal PIN) Enter Programming Mode. Press 1 + [4-digit User ID] + # + [4-digit PIN] + #. Deleting Users

By Card: Enter Programming Mode -> Press 2 + [Read Card] + #.

By User ID: Enter Programming Mode -> Press 2 + [User ID] + #.

Delete All Users: Enter Programming Mode -> Press 2 + 0000 + #. 4. Door Open Modes You can configure how users gain entry: Card Only: Press 3 + 0 + #. Card + PIN: Press 3 + 1 + #. Card or PIN (Default): Press 3 + 2 + #. 5. Setting the Door Delay Time

The delay time determines how long the lock remains open after a valid entry. Enter Programming Mode. Press 4 + [00–99 Seconds] + #. Note: 00 sets the relay to toggle mode (latched). 6. Troubleshooting V2000-C RFID Access Control is a standalone single-door

Forgot Master Code: Power off the device. Press and hold the # key (or the reset button inside the housing) while powering back on. The device will beep, and the Master Code will revert to the factory default.

Card Not Reading: Ensure the card type (EM vs IC) matches the reader frequency and that there is no metal interference behind the mounting surface.

Continuous Beeping: This usually indicates the "Tamper Alarm" has been triggered. Ensure the back cover is securely fastened.

Disclaimer: Security settings should be handled by an authorized technician. Always test the Exit Button and emergency overrides after installation.