The new KES timer has a load limit threshold setting (default 60A). If total house current exceeds this, the timer disconnects the geyser.

Product Category: Geyser / Water Heater Timer (Load Management Device)
Target Use: Residential electric geysers (typically 150L–250L, 2kW–3kW)

If you want, I can:

(Invoking related search suggestions) functions.RelatedSearchTerms("suggestions":["suggestion":"KES geyser timer manual download","score":0.9,"suggestion":"how to wire KES geyser timer to contactor","score":0.86,"suggestion":"geyser timer programming examples off-peak solar","score":0.72])

KES Geyser Load Control Timer Manual: A Comprehensive Guide

Are you looking for a reliable and efficient way to manage your geyser's energy consumption? Look no further than the KES Geyser Load Control Timer. This innovative device allows you to control and optimize your geyser's energy usage, saving you money on your electricity bills while ensuring a steady supply of hot water. In this feature, we'll provide a detailed overview of the KES Geyser Load Control Timer, its benefits, and a step-by-step manual on how to use it.

What is the KES Geyser Load Control Timer?

The KES Geyser Load Control Timer is a smart device designed to regulate the energy consumption of your geyser. It works by switching the geyser on and off at predetermined times, ensuring that it only operates when energy demand is low or when you need hot water. This intelligent device helps reduce peak hour energy consumption, resulting in significant cost savings.

Benefits of Using the KES Geyser Load Control Timer

KES Geyser Load Control Timer Manual

The new KES timer front panel contains:

| Button | Label (Typical) | Function | |--------|----------------|----------| | SET | Menu/Enter | Enter programming mode, confirm settings | | (Up) | Increase/Next | Scroll up or increase value | | (Down) | Decrease/Prev | Scroll down or decrease value | | MODE | Mode/Manual | Switch between Auto, Manual On, Manual Off, Override | | RST | Reset (pinhole) | Factory reset (use a paperclip) |

Display icons explained:


At 9 PM, with a headlamp and a screwdriver, Nina opened the old meter box. The old timer was indeed a KES—a rusted relic. She swapped in the new KES-LCT-9000.

Then came the programming.

The manual said: “To set Load Shedding Profile P1, press MODE for 3 seconds until ‘Prog’ flashes. Use UP/DOWN to set ON time. Press SET to confirm. Repeat for OFF time.”

Simple, right? Wrong.

She discovered that the KES had four overlapping modes:

At 10:17 PM, she accidentally enabled Mode D + Eskom-Sequencer. The geyser clicked on for 17 seconds, off for 43 seconds, then on again—a frantic staccato. The manual’s flowchart on page 27 showed a loop labelled: “If erratic cycling: Perform factory reset (see Appendix B: Prayer).”

The KES geyser load control timer is an indispensable tool for managing energy costs and complying with municipal load reduction schemes. The new models take the guesswork out of scheduling, while giving you manual override power when you really need a hot shower.

Keep this manual accessible – either printed inside your distribution board cover or saved as a PDF on your phone. And remember, while programming is user-friendly, installation must always be left to a qualified electrician to ensure safety and warranty compliance.

Have a specific issue with your new KES timer not covered here? Contact KES technical support with your exact model number (located on the side sticker) and this article’s reference code: KES_LC_NM_2025. kes geyser load control timer manual new


Disclaimer: This article is a general guide. Always refer to the official KES manual supplied with your specific product, as features and terminal assignments may vary between revisions.

The KES Geyser Load Control Timer (specifically model ISG1201) is a specialized device designed to manage water heating and reduce energy bills by preventing operation during peak demand periods. Unlike standard digital timers that require complex manual scheduling, the KES model uses pre-programmed operating profiles to simplify user interaction. Understanding Your KES Geyser Timer (ISG1201)

The device features three primary LED status indicators and four preset profiles: Green LED: Indicates the mains power is ON. Red LED: Indicates the geyser itself is ON and heating.

Flashing Blue LED: Indicates the currently active timer program. Operating Profiles & Programming

The KES ISG1201 includes four factory-set profiles. To select a program, use the Program Select button to cycle through them. Blue LED Pattern Function & Operating Hours Prog 1 1 flash / second

Default Mode: Always ON, but automatically locks out during morning and evening peak hours (Monday–Friday). Prog 2 2 flashes / second

Solar Geyser Mode: Optimized for solar setups. OFF from 08h00 to 15h00 and during all peak demand times. Prog 3 3 flashes / second

Off Mode: Geyser is OFF at all times. Manual override is still available. Prog 4 4 flashes / second

Maximum Savings: ON for only 6 hours on weekdays and 12 hours on weekends. Highly restrictive to minimize costs. Manual Controls & Override

If you need hot water outside of your selected program's schedule, you can use the Override feature.

Activation: Press the Override button to switch the geyser ON immediately.

Duration: The override typically lasts for one hour (or until the next programmed event).

Restrictions: Most KES models block overrides during peak demand times (typically 06:00–08:00 and 18:00–20:00) to comply with load-balancing standards. Installation & Setup Instructions

Warning: Installation involves working with your distribution board (DB) and should be handled by a qualified professional.

Turn Off Power: Switch off the main power and the specific geyser isolator before starting.

Mounting: The unit can be mounted on a DIN Rail inside your DB or a surface-mounted enclosure. Wiring: Connect the Live (L) input from the geyser circuit breaker. Connect the Neutral (N) wire from the DB's neutral bar.

Connect the Load out (bottom of controller) to the geyser wire.

Reset: After powering up, it is recommended to press the Reset button with a small pin to ensure the unit starts in its default state. Common Troubleshooting

Flashing Lights / No Hot Water: If the Blue LED is flashing but the Red LED never turns on, check if you are currently in a "Peak Time" lockout or if you have accidentally selected Program 3 (Always Off).

Battery Backup: The controller features a 60-day battery backup to maintain your settings and clock during load shedding or power failures.

Clock Verification: On some versions, you can verify the Real Time Clock (RTC) by holding the Override and Program buttons together. The new KES timer has a load limit

For further assistance, you can view the KES ISG1201 Guide on Scribd or consult technical forums like MyBroadband for community-sourced solutions. Geyser Load Control Timer ISG1201 Guide | PDF - Scribd

The KES ISG1201 Geyser Load Control Timer is designed to reduce energy consumption by preventing water heating during peak demand periods. It features four pre-defined programs and a manual override for immediate heating. Key Features and Indicators Green LED: Indicates Mains Power is "ON".

Red LED: Indicates the Geyser is currently "ON" and receiving power.

Flashing Blue LED: Displays the active program (e.g., 1 flash = Prog 1, 2 flashes = Prog 2).

Manual Override: Allows the geyser to be powered for up to 60 minutes outside of peak times. Program Operating Modes

The timer comes with four selectable programs that dictate when the geyser is allowed to heat water: Program Status Indicator Operating Schedule (Standard Weekdays) Prog 1 (Default) 1 Flash / 1s

"ON" always except for designated morning and evening peak hours. Prog 2 2 Flashes / 1s

"OFF" from 08:00 to 15:00 and during morning/evening peak hours. Best for solar setups. Prog 3 3 Flashes / 1s

"OFF" all the time except when Manual Override is used. Ideal for vacation or solar use. Prog 4 4 Flashes / 1s

"OFF" during specific blocks (00:00–03:00, 08:00–15:00, 20:00–24:00) and peak hours. Operational Instructions

Manual Override: Press the override button to heat water for 60 minutes. Note that the override will not function during peak demand "lock-out" times to prevent strain on the grid.

Switching Programs: To change the active program, typically you must hold or press specific buttons (like "program" or "override") until the Blue LED flashes the desired number of times.

Real-Time Clock (RTC) Verification: To check the time and day, hold the "override" and "program" buttons together; LED 1 will flash to confirm hours/minutes/day. Installation Overview

Mounting: Can be surface-mounted or installed on a DIN rail within an electrical distribution (DB) board.

Wiring: Requires a jumper from the Geyser Circuit Breaker output to the Controller's Live (L) input, and a Neutral (N) connection from the DB board.

Safety: Always ensure the mains power is switched off before attempting any internal wiring. Geyser Load Control Timer ISG1201 Guide | PDF - Scribd

The KES Geyser Load Control Timer (specifically model ) is designed to reduce electricity consumption by preventing your geyser from heating during peak demand periods. Installation Instructions

Safety First: Turn off the main power at the Distribution Board (DB) and the geyser isolator before starting.

Mounting: The unit can be surface-mounted (e.g., in a ceiling cavity near the geyser) or DIN-rail mounted directly inside the DB panel. Wiring (DB Mount):

Connect the Live wire (Red) from the geyser isolator to terminal L2. Connect the Neutral wire (Black) to the DB neutral bar. Connect the Earth wire to the DB earth bar. Programming & Operation

features four pre-programmed profile options, which you can cycle through using the "Programme Select" button. (Invoking related search suggestions) functions

Standard Peak Lockout: By default, the timer prevents operation during standard peak times: 06:00 – 08:00 and 18:00 – 20:00 (Monday to Friday). Programme Profiles:

Prog 1: Always ON except for peak lockout times (Mon–Fri). Geyser remains ON 24/7 during weekends.

Prog 4: Most restrictive; OFF for most of the day (00:00–03:00, 08:00–15:00, 20:00–24:00) and during peak times. It includes a short weekend "ON" window from 11:00 to 13:00.

Manual Override: Press the Override button to turn the geyser ON for 1 hour.

Note: The override will not function during designated peak demand hours. Verification

To check the Real Time Clock (RTC), hold the "Override" and "Program" buttons simultaneously. The LED will flash to indicate the current hours, minutes, and day of the week. Geyser Load Control Timer ISG1201 Guide | PDF - Scribd

The ISG1201 comes with four selectable profiles indicated by a flashing blue LED:

Prog 1 (Default): Always "ON," but automatically switches "OFF" during peak times (Mon–Fri, 06:00–08:00 and 18:00–20:00).

Prog 2: "OFF" from 08:00 to 15:00 and during all peak times. Ideal for solar geyser setups.

Prog 3: "OFF" at all times by default, except for manual overrides. This is also suitable for solar applications.

Prog 4: "OFF" during specific blocks: 00:00–03:00, 08:00–15:00, 20:00–24:00, and all peak times. Key Controls and Indicators

Programme Select Button: Used to cycle through the four profile options.

Override Button: Provides a 1-hour manual bypass to heat water immediately using the geyser's standard thermostat.

Note: The override is only available outside of designated peak hours. LED Status Lights: Green LED: Mains power is present. Red LED: The geyser is currently receiving power ("ON").

Flashing Blue LED: Indicates the currently active profile (e.g., 2 flashes = Prog 2). Installation Basics

The unit can be installed on a DIN rail inside an electrical distribution (DB) panel or surface-mounted, often in a ceiling cavity near the geyser isolator.

Wiring: Requires a 220V connection to Live (L) and Neutral (N) terminals. The geyser's load wire is then connected to the "Load Out" terminal.

Professional Requirement: It is highly recommended that a qualified electrician perform the installation to ensure safety and insurance compliance.

For further detailed diagrams and technical specifications, you can view the full KES Geyser Timer Instruction Manual on Scribd. Geyser Load Control Timer ISG1201 Guide | PDF - Scribd

Here are a few options for an interesting post, depending on where you are posting (Instagram, Facebook, a Blog, or a Forum).

In the new KES models, load control periods are called “Off-Peak Lockout” zones.

  • If the geyser load exceeds the timer’s direct switching rating, wire the timer to control a suitably rated contactor (timer output to contactor coil; contactor main contacts in series with the geyser’s supply).
  • Connect a local isolator (fused or MCB) sized to the geyser current.
  • Re-check all connections, restore mains, and observe indicators.
  • Set local time and test ON/OFF scheduling and manual override.
  • Safety notes: