A: Yes, but you must use the Mach4 plugin version 1.2.0 or newer. The older Mach3 plugin may cause unexpected resets. Contact your board supplier for the correct plugin.
You may revert to V1.5 using the same procedure. V1.4 rollback requires a full factory reset after downgrade.
If your current system is running V1.4 or earlier and you demand higher speeds, better safety response, or Modbus integration, then upgrading to the Jx-v29 59-ga V1.6 Firmware is a wise decision. The performance gains far outweigh the minor configuration effort. However, if your production environment cannot tolerate even a 1% risk of downtime, stay with your stable version until you can schedule a maintenance window. Jx-v29 59-ga V1.6 Firmware
Always download firmware from official sources, triple-check your hardware revision (some “59-ga” v1.6 files are not backward-compatible with older PCB revisions), and document every change. With careful implementation, the Jx-v29 59-ga V1.6 firmware will breathe new life into your CNC or automation project.
Disclaimer: The information provided in this article is for educational purposes. Firmware updates should be performed by qualified personnel. Always consult your equipment’s original manufacturer documentation before making changes. The author is not responsible for any hardware damage or data loss resulting from the use of this guide. A: Yes, but you must use the Mach4 plugin version 1
A: Indirectly. LinuxCNC uses a different real-time stack. However, if your Jx-v29 board supports Ethernet or serial transparent mode, you can use it as a step generator. Check the hal file examples.
Unlike some firmware updates that reset all parameters, the Jx-v29 59-ga V1.6 retains user calibration data (steps per mm, direction pins, soft limits) during the flash process. However, a full backup is still recommended. Disclaimer: The information provided in this article is
Warning regarding "Unlocking": If you found this guide because you are trying to "unlock" the device from a specific tracking service provider (like Jimi or other IoT platforms), this is often difficult. These devices often have "Lock firmware" that prevents them from connecting to other servers. You would need to wipe the memory completely and flash generic firmware, which carries a high risk of destroying the device's calibration data (RF calibration). Proceed with caution.
Even a stable release can encounter problems due to hardware variations. Here are the most common post-upgrade issues and their solutions:
| Issue | Probable Cause | Solution | | :--- | :--- | :--- | | Screen remains white/blank | Bootloader mismatch or corrupted file | Re-download V1.6 from a different source. Try reflashing with a different SD card (some cards are incompatible). | | Touch is reversed (mirrored) | Orientation register not reset | Enter engineering menu. Look for "Touch Reverse X/Y" or "Mirror Mode" and toggle it off. | | Backlight stays off | PWM frequency changed in V1.6 | The new firmware may expect a different backlight pin mapping. Check the hardware jumper settings on the display board. | | Flickering horizontal lines | Power supply insufficient voltage | Upgrade to a 5V/3A supply. The V1.6 firmware may enable higher refresh rates that draw more peak current. | | Firmware version still shows old number | Incorrect file name or wrong SD slot | Ensure the update file’s name matches the bootloader’s expectation exactly. Try a different SD slot if available. |